INSTRUCTIONS FOR

MOTION SENSOR KIT

  • 2. unscrew fixture to access wires - showing wiring diagram of neutral wires, power in and out, ground wires
  • 3. connect receiver wires to fixture wires - wiring diagram of 5 amp receiver connected to fixture wires with neutral, black, white, blue, power in and out, and ground wires
  • 2. unscrew fixture to access wires - showing wiring diagram of neutral wires, power in and out, ground wires
  • 3. connect receiver wires to fixture wires - wiring diagram of 5 amp receiver connected to fixture wires with neutral, black, white, blue, power in and out, and ground wires
This kit comes pre-connected, but if you need to pair the motion sensor, make sure the receiver is in linking mode by pressing the ‘link’ button on the side of the receiver. Then simply press the pairing button on the motion sensor, shown below:
WIRELESS RANGE:
Up to 30 meters
RADIO FREQUENCY:
902 MHz
POWER SUPPLY:
Battery CR123A 3V
RF POWER MAX:
+3dBm
DETECTION RANGE:
Up to 5 meters
LUX SENSING:
0 to 1000Lux
OPERATING TEMP:
-10°C (45°F)
DIMENSIONS:
65(W) x 65(L) X 39(H) mm
EEP:
A5-07-03
CERTIFICATIONS:
FCC: SZV-STM300U (United States)
IC: 5713A-STM300U (Canada)
RANGE:
50-150 FT (typical)
FREQUENCY:
902 MHz
POWER SUPPLY INPUT RATING:
100-277 VAC 50/60 Hz
OUTPUTS:
1 - 5A Latching Form A Relay
MAX LOADS / CONTACT RATINGS:
RESISTIVE LOAD 10A

TUNGSTEN 1000W

FLUORESCENT 600W

LED LAMP 200W

MEMORY:
LINK UP TO 10 SWITCHES
OPERATING TEMP:
-32° to 122° F (0° to 50° C)
DIMENSIONS:
1.1(L) x 1.6(W) X 3.3(H) inches
CERTIFICATIONS:
ETL: UL 60730 (U.S.)
ETL: CSAc22.2#14-05 (Canada)
CE: IEC 60730
ETL: UL 2043 (Plenum)
IEC61000-4-5 (Surge)
FCC: SZV-STM300U (United States)
IC: 5713A-STM300U (Canada)
WALK TEST MODE
When the product is powered-up for the first time (of after removing the battery), the sensor enters into « Walk Test Mode ». During 3 minutes, the LED will flash every time a motion is detected. Use this feature to find the perfect location, and its efficiency, for your sensor.


LIGHT SENSITIVITY
The RunLessWire PIR Motion Sensor embeds an ambient light sensor, allowing to only detect movement under a luminosity level: If the ambient light is below the limit defined by the potentiometer, an ON or OFF frame will be sent when motion is detected. The feature can be deactivated by placing the potentiometer on position OFF. Default position: OFF
AUTO OFF-TIME SETTING
When linked to a compatible receiver, the ILLUMRA® PIR Motion Sensor is capable of switching the receiver ON when Motion is detected and OFF after a timeout with no motion detected. Please note that the auto-off timer is reset every time motion is detected.To adjust the Auto-Off Time, long press on the « Pairing » button for 3 seconds until the LED indicator illuminates the lens to indicate the sensor is in the « Setting Mode ».While in the « Setting Mode », press the button to cycle to the desired Auto-Off Time. With each press, the LED will blink a certain number of blinks to confirm the current setting (See table below for details)
Auto off-time
30sec
5min
15min
30min
Number of presses after glowing
1st press
2nd press
3rd press
4th press
LED blinks
1
2
3
4
« Setting » Mode will automatically exit and the setting saved, after no action on the button for 5sec. By default, the Auto-Off time is set on 30sec.
Best Practice:
In a hallway, or location place where people spend less time, set up the Auto-Off time to a small value, to automatically switch OFF the light as fast as possible (and save energy). In a meeting room or location where people will be present with less motion, set up the Auto-Off time to a longer value, to avoid the light switching OFF while the room is still occupied. After the Auto-Off timer elapses with no motion detected, the light will automatically turn OFF.
LOW BATTERY INDICATOR
The LED will flash twice every 10sec when the battery need to be replaced.


HEARTBEAT SETTING
The Heartbeat is an automatically triggered frame, and is sent every 30min. It contains information from the sensor, such as current Lux level, battery level and current sensor state (Movement / No Movement). By default the Heartbeat is activated. To deactivate (or activate) the Heartbeat, press 3 times on the « Pairing » button.
If the LED glows 1 time, the Heartbeat will be set OFF. If the LED glows 2 times, the Heartbeat will be set ON.
If you want to change this parameter, press again 3 times on the « Pairing » button.
TEST FUNCTION:
Press and release the SELECT button to toggle receiver (controller) ON and OFF.


SENSOR LINK TEST MODE:
After linking, press the Link button on a sensor 6 times to activate the Link Test Mode. Subsequent presses from any linked sensor will cause the relay to toggle confirming the sensor is linked and testing the reliability
of wireless communications. Link Test Mode will time out after 60 seconds of no activity.


CLEAR ALL LINKS:
1. Activate Simple Link Mode by holding the MENU button until the controller starts toggling.
2. Hold the SELECT button for 10 seconds to Clear All Links from the controller.


SELECTIVE LINK DELETION:
To remove one Link from controller and leave others unaffected:
1. HOLD the MENU button to activate Link Mode. The toggling output confirms Link Mode is active.
2. TRANSMIT the Link Signal by triple pressing the top button on switches or single pressing the Link (or teach) button on sensors. Controller pauses in OFF position for 3 seconds when the link is deleted, then toggling resumes.
3. WAIT 30 seconds for Link Mode to exit automatically (toggling stops).


REPEATER MODE:
Repeater function is DISABLED by default and may be enabled on specific controllers to extend the range by
retransmitting all packets 1 or 2 times. Repeater mode may be changed using Advanced Setup instructions.
Transmit - -> Repeater 1x - -> Repeater 2x - -> Receive 


ADVANCED SETUP
Advanced Setup uses the Status LED to navigate a hierarchy of menus with blink patterns in one of 3 colors: Amber, Green, and Red. The relay output does not toggle while using Advanced Setup. Navigation overview:
     1. Hold MENU button 15 seconds until Status LED blinks Amber pattern.
     2. Press SELECT button to cycle through blink count options.
     3. Press MENU button to enter/save menu item.
     4. Hold MENU for 5 seconds to exit menu option.


1 - ACTIVATE ADVANCED SETUP
     A. Hold MENU button 15 seconds until Status LED blinks Amber pattern.
     B. Jump to 2 - Link Mode or 3 - Setup.


2 - LINK MODE: AMBER MENU BLINKS 1-5
     A. Press SELECT button to cycle blink count and choose a Link Mode. Different devices may be linked in       different modes.
     B. Transmit Link Signal with fast triple press of switch button or single press of Link button on sensors.   Status LED will pause Green when link is added. If Link Signal is transmitted a second time, Status LED will   pause Red indicating link is removed.
     C. Optional - Press MENU button to see Green blinks indicating number of devices linked in the active   mode. Red blink means no devices linked. Hold MENU button 5 seconds to return to Amber Menu.
     D. Wait 60 seconds or hold MENU button for 5 seconds to return to Operating Mode.


3 - SETUP: AMBER MENU BLINKS 6-7
     A. Press SELECT button to cycle to Config (6 Amber blinks) options.
     B. Press MENU button to activate Green Menu.
     C. Press SELECT button to cycle through Green blink options.
     D. Press MENU button to activate Red Menu.
     E. Press SELECT button to cycle through Red blink options or hold SELECT button to adjust level if   applicable.
     F. Press MENU button to save selection.
     G. Hold MENU button for 5 seconds to return to Green Menu.
     H. Hold MENU button for 5 seconds to return to Amber Menu.
     I. Hold MENU button for 5 second