INSTRUCTIONS FOR

DETACHABLE REMOTE SWITCH KIT


ALL KITS COME PRE-LINKED, ONLY DO THIS TO ADD OR REMOVE SWITCHES OR CONTROLLERS

The receiver must be connected to a power source to turn on during the linking process. Once the receiver has been wired into your system, turn breaker back on to check for power before linking sensor.


LINK/UNLINK SWITCH TO RECEIVER:

  1. Press button on receiver for 3 seconds until receiver begins to toggle on/off.

  2. Press TOP of switch 3 times quickly to link switch to receiver, or BOTTOM of switch 3 times to unlink.

  3. The LED and output will pause ON for 3 seconds if linked, or OFF for 3 seconds if unlinked.

  4. Wait for linking mode to time out (30 seconds).

  5. Test switch to ensure it’s linked properly.

RANGE:
50-150ft (typical)
FREQUENCY:
902 MHz
POWER SUPPLY:
SELF-GENERATED WHEN SWITCH IS PRESSED
OUTPUT CHANNELS:
Link to any number of receivers in range
BUTTONS:
2 BUTTONS (1 ROCKER)
ADDRESSING:
FACTORY SET UNIQUE ID (1 of 4 Billion)
OPERATING TEMP:
-4° to +131°F (-20° to +55°C)
DIMENSIONS:

Mounting Plate:

1.71(W) x 4.19(L) x 0.11(H) inches

Remote Switch:

1.3(W) x 2.61(L) x 0.62(H) inches

RADIO CERTIFICATION:
FCC:  VJC-E9TS1M (UNITED STATES)
RANGE:
50-150ft (typical)
FREQUENCY:
902 MHz
POWER SUPPLY INPUT RATING:
100-240VAC / 60Hz
RELAY OUTPUT:
1 Form A Relay 5A
MAX LOADS / CONTACT RATINGS:

Resistive Load 5A

Tungsten 600W

Fluorescent 600W

LED Lamp 200W

MEMORY:
Link up to 10 Switches
OPERATING TEMP:

-40°F - 104° F (-40°C - 60°C)

DIMENSIONS:

1.6(W) x 3.3(H) x 1.1(L) inches

RADIO CERTIFICATION:
FCC (US)

CONFIRM RECEIVER IS WIRED CORRECTLY:
Test the status light on the receiver by pressing the CTRL button. Green means the output should be ON, no light means the output should be OFF. If the status light is not working, that indicates the power is not ON, wiring is incorrect, or the receiver has been damaged. Try tapping the button a few times to get the light to
turn on. If the status light turns ON, but the light doesn’t turn ON, the wiring could be incorrect or it could be a bulb failure.
CONFIRM SWITCH IS FUNCTIONAL:
Press the top of the switch to turn the receiver ON and the bottom of the switch to turn it OFF. If the receiver doesn’t respond, the switch may not be linked